Austin Insulators Inc. home | about | products | support |contact us    

Austin Insulators Inc.
suppliers of RF insulators and transformers since 1933

   
       

 

Products:  
Guyed Tower  
Base Insulator  
TYPES:  
A-3663-B  
A-4447-B  
A-3820-R  

Profile 
Dimensions 

 

Austin Base Insulators for Guyed Radio Towers and Masts
TYPES A-3663-B, A-4447-B, A-3820-R

 

   
         
       
  Dimensions    
 
Type A B C D E F Rocking Plate Mast Fixing
(Centre Pin)
Insulator Mounting Net Weight
A-3663-B 35"
889 mm
30"
762 mm
6.5"
165 mm
dia.
18"
457 mm
dia.
17"
432 mm
dia.
  1-3/8"
(35mm) thick
12-1/4"
(311mm) dia.
1-1/2" (38mm) dia.
protruding
1-1/2" (38mm)
above rocking plate
13" (330mm)
clearance dia.
3 holes drilled
1-1/8" (29mm)
on 15" (381mm) BCD
575 lb
260 kg
A-4447-B 35"
889 mm
30"
762 mm
6.5"
165 mm
dia.
21"
533 mm
dia.
21"
533 mm
square
18"
457 mm
1-5/8"
(41mm) thick
15"
(381mm) dia.
1-1/2" (38mm) dia.
protruding
1-1/2" (38mm)
above rocking plate
16" (406mm)
clearance dia.
4 holes drilled
1-3/8" (35mm)
square base
925 lb
420 kg
A-3820-R 35.5"
902 mm
30"
762 mm
6.5"
165 mm
dia.
27.5"
699 mm
dia.
27.5"
699 mm
square
24.5"
622 mm
2-1/2"
(64mm) thick
20"
(508mm) dia.
2" (51mm) dia.
protruding
1-1/2" (38mm)
above rocking plate
22" (559mm)
clearance dia.
4 holes drilled
1-5/8" (41mm)
square base
2450 lb
1110 kg
   
 

  • BCD = Bolt Circle Diameter
  • All Austin Insulator bases are designed for VLF, LF, and MF use, and are conservatively rated. Choose the unit that will meet your requirements for working download, working uplift, shear and RF operating voltage.
  • If you have a requirement which we do not seem to meet or you wish us to recommend a suitable insulator, please contact us and supply us with as much relevant information as possible.
   
       
 

home | about | products | support | contact us

   
       